Introduction:
Melting point is the temperature of something turning to liquid from solid. Testing it is the main method to detect some characters such as purity etc. It is suitable for testing Melting points of drug, spice and dye etc.
Model:RD-1
Applicable standard:
National standard( Chinese codex ) /2010
Corporate standard(Thickness tester) Q/12XQ0185-2010
Features:
Testing the temperature with high-precision sensor. emending nonlinear error automatically.
Using auto frequency-conversion control technology, with high accuracy in controlling temperature and little linear error in heating speed.
Auto-memorizing and noting preset data and melt point, holding without power.
Auto magnetism stirrer, with the bath oil even in temperature.
Auto-preset temperature, auto-heat, display preset and real-time data alternately in time.
Automation: auto-test, auto-diagnose, auto-alarm
Specifications:
Range of melting point (50~270)℃
Accuracy <200℃ ≯±0.5℃
≥200℃ ≯±1.0℃
Usage temperature (15~35)℃
Range of preset temperature (50~260)℃
Oil bath methyl silicone oil
Oil bath cup 250ML high beaker
Rate (0.5、1.0、1.5、3.0)℃/min
Accuracy of Rate ≤10%
Power of the heater 200W
Power 220V/50Hz/500W
Dimension (320*180*290)mm3
Model:RY-1
Applicable standard:
Corporate standard(Thickness tester) Q/12XQ0185-2010
Features:
Test temperature with standard mercury thermometer.
Adjust heating voltage by a knob.
Display voltage with a analog voltmeter.
Observe Melting sample by a magnifier.
Test three samples at once.
Specifications:
Range of melting point (50~300)℃
Accuracy ±1.0℃
Usage temperature (15~35)℃
Rate (1.0、2.0、4.0、6.0)℃/min
Power of the heater 100W
Power 220V/ 50Hz/ 100W
Dimension (190*120*200)mm3
Model:RY-2
Applicable standard:
Corporate standard(Thickness tester) Q/12XQ0185-2010
Features:
Test temperature with standard mercury thermometer.
Adjust heating voltage by keystorke.
Display voltage with a digital voltmeter.
Observe Melting sample by a magnifier.
Test three samples at once.
Specifications:
Range of melting point (50~300)℃
Accuracy ±1.0℃
Usage temperature (15~35)℃
Rate (1.0、2.0、4.0、6.0)℃/min
Power of the heater 100W
Power 220V/ 50Hz/ 100W
Dimension (190*120*200)mm3
The other models we supply: